Benchmark Media Systems, Inc.

DAC1/ADC1 Fuse Recall

February 6, 2006

Benchmark has issued a recall for incorrect value fuses included with specific DAC1 and ADC1 products manufactured between September 23, 2005 and February 3, 2006. Though no incidences of personal or propery damage have been reported to Benchmark at this time, use of an incorrect value fuse is a potentially serious safety risk, including the risk of fire.

The following products may be affected:
Part #DescriptionSerial #s
500-14000-000DAC1 Black RM 110V41575 - 42475
500-14000-100DAC1 Silver 110V41575 - 42475
500-14000-200DAC1 Black 110V41575 - 42475
500-14200-000ADC1 110V00062 - 00124
500-14200-002ADC1 220V00062 - 00124

If you have any of the above products, immediately discontinue use and examine the fuses, including the spare fuses shipped with the product. The proper fuse for DAC1 110V and ADC1 110V/220V operation should have "500mA" stamped on the metal end cap as illustrated below. Do not use any other value fuse for this purpose. If you find a fuse of any other value, permanently discontinue use of that fuse and or your dealer for free replacement fuses.

©2007 Benchmark Media Systems, Inc.